EMFFIX with PRINT option

From: Andreas Morsch (morsch@mail.cern.ch)
Date: Tue Dec 20 2005 - 14:37:32 CET

  • Next message: Helmut Vincke: "Abort from GTEMFF"

    Dear FLUKA-developers,

    it seems there is a problem with EMFFIX using the PRINT option.
    I get:

    Subscript out of range on file line 615, procedure fixtmx.f/fixtmx.
    Attempt to access the -267-th element of variable bucint.

    for all tested combinations of energy cuts and EMFFIX settings.

    Could you please have a look.
    Best regards -
    Andreas Morsch

    Here an input example:

    MATERIAL 1.032e+00 18.0 POLYSTYR
    COMPOUND -0.922579 5.0 -0.077421 3.0 POLYSTYR
    PPCUTM = 1e-05, PPCUTE = -1
    EMFCUT 0.0 0.0 0 18.0 18.0 1.0PHOT-THR
    PAIRBREM 3.0 0 1e-05 18.0 18.0
    IONFLUCT 1.0 1.0 1.0 18.0 18.0
    DELTARAY 1e-05 0.0 0.0 18.0 18.0 1.0
    *Options for sensitive medium
    EMFFIX 18.0 0.050 0.0 0.0 0.0 0.0PRINT


  • Next message: Helmut Vincke: "Abort from GTEMFF"