Re: [fluka-discuss]: Comscw - RULL of exactly 1GeV

From: <Meyer.Se_at_physik.uni-muenchen.de>
Date: Thu, 06 Apr 2017 15:52:53 +0200

Dear Mary and Alfredo,

thank you very much for your explanations. Indeed, RULL was no energy
deposition in this case. I could solve it by checking ISCRNG.
Unfortunately I can not use the built in scoring since I need to
integrate the energy deposition only for a fraction of particles
before saving the output. I will give a look at MGDRAW as suggested.

Best,
Sebastian



Quoting me_at_marychin.org:

> Dear Sebastian,
>
> RULL=1 indeed looks like a number too nice and round to be true. The
> first thing to check is if the unit is really GeV. You might like to
> write out ISCRNG and see. My wild guess is that ISCRNG could be 2,
> which means 1 star, not 1 GeV.
>
> When scoring RULL with comscw, typically we filter with ISCRNG and
> JSCRNG to avoid counting more than we actually intend.
>
> :) mary
>
> On 2017-04-06 19:12, Meyer.Se_at_physik.uni-muenchen.de wrote:
>> Dear FLUKA community,
>>
>> I am simulating a helium-ion beam and I score the energy deposition in
>> several air regions (using the comscw routine). I realized cases for
>> which the energy deposition (RULL) of a 4-helium is exactly 1GeV,
>> which is already strange since the beam energy is just around
>> 170MeV/u. In addition, I found that ICALL is 420 and not 131 as all
>> other energy deposition events.
>>
>> Can someone explain me what happened?
>>
>> Kind regards,
>> Sebastian
>>
>>
>> --
>> Sebastian Meyer
>> PhD student
>>
>> Ludwig-Maximilians-Universität München
>> Chair for Experimental Physics - Medical Physics
>> Am Coulombwall 1
>> D-85748 Garching
>>
>> room: 125
>> phone: (+49) 89 289-54022
>> e-mail: Meyer.Se_at_physik.uni-muenchen.de
>>
>>
>> __________________________________________________________________________
>> You can manage unsubscription from this mailing list at
>> https://www.fluka.org/fluka.php?id=acc_info
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info


-- 
Sebastian Meyer
PhD student
Ludwig-Maximilians-Universität München
Chair for Experimental Physics - Medical Physics
Am Coulombwall 1
D-85748 Garching
room:  125
phone: (+49) 89 289-54022
e-mail: Meyer.Se_at_physik.uni-muenchen.de
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Apr 06 2017 - 16:50:39 CEST