[fluka-discuss]: Stopping power ratios from inline calculations

From: Ferreira De Almeida Lourenco, Ana <am.lourenco_at_ucl.ac.uk>
Date: Tue, 27 Jun 2017 14:09:37 +0000

Dear Fluka experts,

Stopping power ratios are important for dosimetry using ionization chambers since they are part of the conversion of ionization in air to dose to water.

Ideally the cavity integrals required for the stopping power ratio calculation are all calculated inline within the Monte Carlo simulation avoiding problems with the resolution of binning.

I would like to ask if it would be possible to compute stopping power ratios directly from inline calculations using FLUKA rather than first calculating the fluence differential in energy and then separately averaging the stopping powers over the calculated spectra?

Many thanks,
Ana



__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Jun 27 2017 - 18:16:17 CEST