Hi Ana,
you can dump the dE/dx tables for the materials used in your input, using the DELTARAY card, and enable the sdum: PRINT
Vasilis
________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Ferreira De Almeida Lourenco, Ana [am.lourenco_at_ucl.ac.uk]
Sent: Tuesday, June 27, 2017 16:09
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Stopping power ratios from inline calculations
Dear Fluka experts,
Stopping power ratios are important for dosimetry using ionization chambers since they are part of the conversion of ionization in air to dose to water.
Ideally the cavity integrals required for the stopping power ratio calculation are all calculated inline within the Monte Carlo simulation avoiding problems with the resolution of binning.
I would like to ask if it would be possible to compute stopping power ratios directly from inline calculations using FLUKA rather than first calculating the fluence differential in energy and then separately averaging the stopping powers over the calculated spectra?
Many thanks,
Ana
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info