RE: [fluka-discuss]: Problems with USRBDX

From: Vasilis Vlachoudis <Vasilis.Vlachoudis_at_cern.ch>
Date: Tue, 4 Jul 2017 13:01:21 +0000

Dear Javier,

as I told you in the previous email, the _tab.lis contains the two contributions
from the low-energy neutrons and everything else

So the first 260 bins follow the low-energy neutron group structure chapter 10 of the fluka manual (almost logarithmic from 1e-14 to 0.02GeV) , and immediately they are followed by the histogram you requested from 0 to 0.7GeV in 400 bins with a linear step of 0.00175 GeV

Unfortunately the bins do not match, so you should do the integral of the low energy neutrons for each bin of the other particles.

Best regards
Vasilis







Vasilis Vlachoudis
Dep EN, CERN
CH-1211 GENEVA 23
SWITZERLAND

Phone: +41-22 767 9851
GSM: +41-75 411 4378
Fax: +41-22 766 9644

________________________________
From: Javier Lozano Díaz [jlozano_at_clpu.es]
Sent: Tuesday, July 04, 2017 12:05
To: fluka-discuss_at_fluka.org; Vasilis Vlachoudis
Subject: Fwd: [fluka-discuss]: Problems with USRBDX

Hello again Fluka experts.

Sorry but I continue with this doubt

I write again the email.

"Thank you for the answers but I continue having doubts in the first one:

I use electrons and protons as a source, I have activated the photoreactions and it is created neutrons, but anyway if you see the energy binning, being score is "LinE LinAngle", is not linear, for example, Emin=30 Emax=300 in 100 bin, you can see that the difference is sometimes 0.5, others 0.2, the last are 1 or others the diferecence is 0. So you can not obtain the dose as sum of all contributions and then multiplique By the width of the bin.

Thank you again.

Regards."

---------- Forwarded message ----------
From: Javier Lozano Díaz <jlozano_at_clpu.es<mailto:jlozano_at_clpu.es>>
Date: 2017-06-29 15:30 GMT+02:00
Subject: Re: [fluka-discuss]: Problems with USRBDX
To: Vasilis Vlachoudis <Vasilis.Vlachoudis_at_cern.ch<mailto:Vasilis.Vlachoudis_at_cern.ch>>
Cc: "fluka-discuss_at_fluka.org<mailto:fluka-discuss_at_fluka.org>" <fluka-discuss_at_fluka.org<mailto:fluka-discuss_at_fluka.org>>


Hello Vasilis.

Thank you for the answers but I continue having doubts in the first one:

I use electrons and protons as a source, I have activated the photoreactions and it is created neutrons, but anyway if you see the energy binning, being score is "LinE LinAngle", is not linear, for example, Emin=30 Emax=300 in 100 bin, you can see that the difference is sometimes 0.5, others 0.2, the last are 1 or others the diferecence is 0. So you can not obtain the dose as sum of all contributions and then multiplique By the width of the bin.

Thank you again.

Regards.

2017-06-28 9:11 GMT+02:00 Vasilis Vlachoudis <Vasilis.Vlachoudis_at_cern.ch<mailto:Vasilis.Vlachoudis_at_cern.ch>>:
Dear Javier,

1st. Scoring quantities that uses all particles in USRBDX, USRTRACK...
     for low energy neutrons (20MeV) will use always the neutron group structure,
     while for all other particles it will use the binning that you requested.
     Therefore you see in your case 260 n groups +400 bins

2nd. FLUKA doesn't have the impact ionization cross section for protons
     so what you get at high energies of protons is indirectly through other
     processes.

Vasilis
________________________________
From: owner-fluka-discuss_at_mi.infn.it<mailto:owner-fluka-discuss_at_mi.infn.it> [owner-fluka-discuss_at_mi.infn.it<mailto:owner-fluka-discuss_at_mi.infn.it>] on behalf of Javier Lozano Díaz [jlozano_at_clpu.es<mailto:jlozano_at_clpu.es>]
Sent: Tuesday, June 27, 2017 08:31
To: fluka-discuss_at_fluka.org<mailto:fluka-discuss_at_fluka.org>
Subject: [fluka-discuss]: Problems with USRBDX

Hello Fluka experts.

I was simulated a shielding with an electron beam and I use some USRBDX scoring cards. The problem is when I check the result of tab.list or sum.list of this detectors and I find more binns in Energy than I have written in the card. For example if I put 1200 fluka count 1650, I have reduced to 400 but then appears 660, if you check the datas one by one you will find binn with the same energy interval (for example 2.3E-2 to 2.3E-2). I don't know why.

I want to calculate de dose before and after the shielding and I'm trying to sum all the points in each interval of energy but I find that after the first layer I have the same dose that after the shielding element. This is a good way for obtain the dose?

I add some folders

2 nd problem: k alpha line of copper

In the same configuration (changing the first layer for copper) I send a proton beam on a copper target in order to see the k alpha line (8.02 KeV). I am able to see the k alpha line with a proton energy more than 30 MeV. Under this energy it is impossible to see the k alpha line.
The card I am using to see the k alpha line are the following: EMF, EMFFLUO, EMFCUT prod, EMFCUT transport.

I would like to know why I can not see them with lower energy and which card should I add to see k alpha with a proton beam less than 30 MeV and if possible for 5 MeV proton beam, on the other hand, if I use an electron beam with a hundred of KeV, in this case I can see the K alpha without problems.

Kind Regards



--
D. Javier Lozano Díaz
Técnico de apoyo en Radioprotección
Centro de láseres Pulsados Ultracortos (CLPU)
Calle Adaja nº8 C.P. 37185 Villamayor, Salamanca.
Edificio M5, Parque Científico USAL.
Tel: 923 338 121 Ext: 26
E-mail: jlozano_at_clpu.es<mailto:jlozano_at_clpu.es>
www.clpu.es<http://www.clpu.es>
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Jul 04 2017 - 16:06:09 CEST