Fwd: [fluka-discuss]: Scoring for cosmic ray dose equivalent

From: Luigi Salvatore Esposito <luigi.salvatore.esposito_at_cern.ch>
Date: Mon, 14 Aug 2017 12:42:04 +0000

Dear Tolga,
sorry for the late replay but I overlooked your replay.

From what I can understand, you are interested to dose-eq due to the cosmic rays.
Therefore I assume that you have no RADDECAY card in your input, which is needed to simulate radioactive decays.
As a result, the DCYSCORE cards should not be present as well.
The results would anyhow only account for the prompt phase (Note 6 of DCYSCORE in the manual).

You should provide different names the scorings: USRBIN/EVENTBIN have the same name. Otherwise this is somehow vague when they are associated to AUXSCORE.

Most importantly, it makes no sense to try to compute dose-eq with a USRYIELD since dose-eq is defined as the particle fluence (*not* yield) folded with energy dependent coefficients.

Let me conclude that it would be more effective to send the input file (ideally a minimum version of it) in order to better provide a better assistance.

Best regards, luigi

Begin forwarded message:

From: HASAN TOLGA ADA <hasan.tolga.ada_at_gazi.edu.tr<mailto:hasan.tolga.ada_at_gazi.edu.tr>>
Subject: Re: [fluka-discuss]: Scoring for cosmic ray dose equivalent
Date: 10 August 2017 at 13:46:14 GMT+2
To: Luigi Salvatore Esposito <luigi.salvatore.esposito_at_cern.ch<mailto:luigi.salvatore.esposito_at_cern.ch>>

Dear Luigi,

I looked at the documents before, and me and my friends try to calculate the dose-eq several times but we could not get any result.

I have all particle flux from cosmic rays on the ground level but I could not convert to dose eq.

The attached files include out last scoring try about our study. I'll be really glad if you have chance to look at the attacted files for giving us some feedback.

Best regards.
Tolga

________________________________
Kimden: "Luigi Salvatore Esposito" <luigi.salvatore.esposito_at_cern.ch<mailto:luigi.salvatore.esposito_at_cern.ch>>
Kime: "HASAN TOLGA ADA" <hasan.tolga.ada_at_gazi.edu.tr<mailto:hasan.tolga.ada_at_gazi.edu.tr>>
Gönderilenler: 9 Ağustos Çarşamba 2017 0:12:41
Konu: Re: [fluka-discuss]: Scoring for cosmic ray dose equivalent

Dear Tolga,
it’s difficult trying to help you since you didn’t report any details about your problem.

I recommend you to give a look to the slides<https://indico.cern.ch/event/604018/contributions/2435691/attachments/1395454/2242757/08_Scoring_2017.pdf> about the scoring at last FLUKA course.
And, of course, feel free to post again if you have a more specific question.
Best regards, luigi


On 7 Aug 2017, at 17:22, HASAN TOLGA ADA <hasan.tolga.ada_at_gazi.edu.tr<mailto:hasan.tolga.ada_at_gazi.edu.tr>> wrote:

Dear FLUKA users,

I'll try to calculate dose equivalent for the cosmic rays on FLUKA. However I have some problems with the scoring. Here is the main problem, with the help of manual and the notes in the website, I try to make the correct scoring but I can't.

As you can understand that I am new in FLUKA and I couldn't have chance to attend neither beginner nor advanced courses.

I will be really greatful if you dear users can help me for my problem.

Best regards
Tolga

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info



[cid:3436287C-1E6F-4825-83D8-AE70E0337258_at_ad.local][cid:DD2C7B00-A863-4601-BB40-D09A9A46DB66_at_ad.local]




__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info

flair 1.png
(image/png attachment: flair_1.png)

flair 2.png
(image/png attachment: flair_2.png)

Received on Mon Aug 14 2017 - 16:43:55 CEST

This archive was generated by hypermail 2.3.0 : Mon Aug 14 2017 - 16:44:02 CEST