Dear Fluka experts,
I am doing a simulation where the organ dose in a voxel-based human phantom is calculated in an Isotropic-emitted photon field.
But when a run starts,an error is encountered and the output file shows that " Abort called from FLKAG1 reason 3RD: NRLTGG > 2000 Run stopped!".
When i attempted to reduce the simulation particle number(e.g.,1E5),the run is good.
I checked the FLUKA Manual and discuss lists but did not find a possible explanation.
The input file,output file and other relevant files are attached.Any suggestion would be appreciated. Thank you very much!
Best Regards
Yang Bo