Re: [fluka-discuss]: Errors in bremsstrahlung simulation

From: Mikhail Polkovnikov <pmk_at_ihep.ru>
Date: Mon, 4 Dec 2017 13:41:50 +0300

On 30.11.2017 06:24, iaz5_at_tpu.ru wrote:
>
> Dear Fluka experts,
>
> I have the source of electron, tungsten target and some geometry. In
> my simulation, I'm trying to calculate such characteristic as:dose
> rate, spectrum of photons in some part of geometry. But it seems, that
> this model is broken. Photon are hindered by iron, lead(and it's
> right), but not by the steel(it is not correct).
>
> Could you, please, tell me, where is my errors in Fluka input code?
>
> Best regards, Ivan
>
Dear Ivan,

USRTRACK is a fluence estimator, not dose. Use USRBIN as a dose estimator.

There is no dose in vacuum material (your detect region).


Best regards,

Mikhail