[fluka-discuss]: An error about the use of voxel-based human phantoms in FLUKA

From: 杨博 <b-yang12_at_mails.tsinghua.edu.cn>
Date: Mon, 8 Jan 2018 11:27:50 +0800 (GMT+08:00)

    Dear Fluka experts,

 

I am doing a simulation to calculate the organ dose of a voxel-based human phantom in an Isotropic-emitted photon field.

  when a run starts,an error is encountered and the output file shows that " Abort called from FLKAG1 reason 3RD: NRLTGG > 2000 Run stopped!".

  But the run is good when reducing the simulation particle number(e.g.,1E5).

I checked the geometry by running the geometry debugger, and did not find any error in geometry.

The input file,output file and other relevant files(including writegoelm.f and CT data) are attached.

Any suggestion would be appreciated. Thank you so much!




Best Regards

Yang Bo










__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info

Received on Mon Jan 08 2018 - 08:14:24 CET

This archive was generated by hypermail 2.3.0 : Mon Jan 08 2018 - 08:14:31 CET