Re: [fluka-discuss]: NaI detector response, mgdraw, and endraw

From: Mikhail Polkovnikov <pmk_at_ihep.ru>
Date: Thu, 23 Aug 2018 13:06:11 +0300

On 21.08.2018 22:58, Felicia Sutanto wrote:
> Dear FLUKA users,
>
> I am a newbie and I have a question about MGDRAW and ENDRAW.
>
> I am trying to simulate a very simple case (input file is attached):
> 661.7 keV photon at the center of a spherical NaI detector (radius = 5cm)
>
> The purpose of this exercise is only to familiarize myself with the
> collision tape.
> I try to tally the energy deposited by summing over the DTRACK in
> MGDRAW and RULL in the ENDRAW. The result is attached
> (fluka_nai_result.pdf).
>
> I also try to do the same simulation in Geant4 and the result is also
> attached (geant4_nai_result.pdf). It seems that the Compton continuum
> is missing in FLUKA...
>
> Am I supposed to maybe include certain physics in FLUKA?
>
> Best regards,
> FS
>
>
>
>
>
>
Dear Felicia,

You can check an energy deposition process by adding a DETECT card.

*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....
DETECT           0.0    1.E-05    1.E-03    1.E-06 1.    TARGETEDEP

How do you process the MGDRAW, ENDRAW and EEDRAW entries within the user
routine, and how do you process the collision tape itself? Both DETECT
and user dump work fine for me.


Best regards,

Mikhail


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Aug 23 2018 - 13:14:44 CEST

This archive was generated by hypermail 2.3.0 : Thu Aug 23 2018 - 13:14:50 CEST