Dear Shuoyang Wei,
You must set the status parameter as OLD in the OPEN card, otherwise
FLUKA unable to open your data file.
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....
OPEN 18. OLD
electron.dat
The FLUKA manual also recommends use IO unit higher than 20, for example 93.
As a result SOURCE and OPEN cards might have been as follows:
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....
OPEN 93. OLD
electron.dat
SOURCE 93.
Best regards,
Mikhail
On 11.09.2018 03:03, 魏朔阳 wrote:
> Dear Mikhail,
>
> Thanks for your help, but after I corrected the filename, there are
> still errors when running input files.
> Could you please point out what's wrong with my files? Related files
> are attached.
>
> Best regards
>
> Shuoyang Wei