Re: [fluka-discuss]: doubts_on_INP_file

From: George Kharashvili <georgek_at_jlab.org>
Date: Fri, 1 Mar 2019 16:39:33 +0000

Dear Sougata,


In your current setup you are scoring all energy deposited in the air region called VOL. I'm not sure I understand how this can be used to study backscatter. May be you can elaborate.


Regards,

George

________________________________
From: owner-fluka-discuss_at_mi.infn.it <owner-fluka-discuss_at_mi.infn.it> on behalf of Sougata <sougata_at_barc.gov.in>
Sent: Friday, March 1, 2019 3:42:50 PM
To: Fluka Discuss
Cc: Owner-fluka Discuss
Subject: [fluka-discuss]: doubts_on_INP_file

Dear FLUKA experts,

I want to evaluate back scatter material effect on dose due to electron
/ beta. I am varying back scatter thickness and scoring energy
deposition for different back scatter thickness. But my experimental and
theoretical data is not matching (variation of around ~ 10%). Please
check and suggest changes in input file (attached).

--
SOUGATA RAKSHIT / सौगत रक्षित
Scientific Officer(D) / वैज्ञानिक आधिकारीक(D)
RSSD / आर एस एस डि
Bhabha Atomic Research Centre / भाभा परमानु अनुसंधान केंद्र
Mumbai-400 085 / मुंबई-400 085
Tel: +91-022-2559 2214/ दूरभाष: +91-022-2559 2214

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Mar 01 2019 - 18:59:35 CET