RE:[fluka-discuss]: Re: dose

From: Ricardo Manuel Dos Santos Augusto <r.s.augusto_at_cern.ch>
Date: Sun, 12 May 2019 18:47:38 +0000

Dear Nacira,

In the FLUKA pdf online manual (p. 269): "... Doses will be expressed in GeV/g per unit primary weight. To obtain dose in Gy, multiply GeV/g by 1.602176462E−7".

Regarding the second part of your query, the manual (p. 222) states that: "If decays are simulated in semi-analogue mode, detector results are expressed per unit primary weight (possibly scoring together prompt and decay particles, if requested by DCYSCORE with WHAT(1) = –1.0). If decays are instead calculated for requested cooling times, the results are expressed per unit time (pSv/s, cm−2 /s, Bq, etc.)".

You will find more information on how to use decay related cards in the following slides:
https://indico.cern.ch/event/694979/contributions/2927152/attachments/1657658/2654336/Activation_2018.pdf

Kind regards,
Ricardo

               
//Ricardo dos Santos Augusto
TRIUMF-EH&S TRL Rr-7
Office: +1 604 222 10 47 (6375)
Mobile: +1 604 338 50 57
4004 Wesbrook Mall,
Vancouver, BC V6T 2A3, Canada//
________________________________
De : owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] de la part de Nacira HANOUF [n.hanouf_at_ump.ac.ma]
Envoyé : dimanche 12 mai 2019 19:00
À : fluka-discuss_at_fluka.org
Objet : [fluka-discuss]: Re: dose

with these three lines, will the estimator produce data for total dose rate?

RADDECAY 1.
DCYTIMES 0.
DCYSCORE 1. dose dose USRBIN

[https://ipmcdn.avast.com/images/icons/icon-envelope-tick-round-orange-animated-no-repeat-v1.gif]<https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail> Garanti sans virus. www.avast.com<https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail>

Le dim. 12 mai 2019 à 18:38, Nacira HANOUF <n.hanouf_at_ump.ac.ma<mailto:n.hanouf_at_ump.ac.ma>> a écrit :
Dear FLUKA experts,
 I am lost on how to normalize the results of DOSE obtained from USRBIN card that convert DOSE to dose rate. As far as I'm concern the results are in GeV/g/primary but i need them in Gy/h.I have attached my input file.
Any comment will be appreciated.
]

[https://ipmcdn.avast.com/images/icons/icon-envelope-tick-round-orange-animated-no-repeat-v1.gif]<https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail> Garanti sans virus. www.avast.com<https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail>

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Sun May 12 2019 - 21:51:36 CEST

This archive was generated by hypermail 2.3.0 : Sun May 12 2019 - 23:49:09 CEST