Re: [fluka-discuss]: minimum allowable gamma transport cutoff in the EMF card in compliance with the minimum energy in DETECT card

From: Paola Sala <paola.sala_at_mi.infn.it>
Date: Thu, 5 Mar 2020 17:28:30 +0100

Hello
no, sorry. the present lowest transport limit for photons is 100 eV
Regards
Paola
> Dear Fluka Experts,
>
>
>
> I am using a charcoal source and the maximum gamma energy of the system is
> 50 keV. Since I want pulse height spectra, I have given in DETECT card
> WHAT (4) (E cut) = 1E-9; WHAT (3) (E max) = 50E-6; WHAT (2) (E min) =
> 1E-9. Now, in the EMF cut card, for transport cut off what value should I
> give as minimum gamma cut off? Can I set this value as 1E-9 ? Please note,
> I have chosen EM – CASCA for simulation.
>
>
>
> Thanks and Regards
>
>
>
> ~~~~~~~~~~~~~~~~~~~~~~~~~
>
> Riya Dey
>
>
>
>


Paola Sala
INFN Milano
tel. Milano +39-0250317374
tel. CERN +41-227679148

__________________________________________________________________________