RE: [SPAM] Re: [fluka-discuss]: comparison of photon fluence from mgdrawBDX and USRBDX USRBDX

From: gcchauthwani <gcchauthwani_at_npcil.co.in>
Date: Fri, 11 Sep 2020 14:25:23 +0530

Respected All,
Is it possible to estimate the neutron spectrum of different types of
nuclear reactors viz. CANDU type, BWR, PWR and fast reactor using FLUKA? If
yes, can anyone please let me know how it can be done?


Regards,
Gyan

-----Original Message-----
From: owner-fluka-discuss_at_mi.infn.it [mailto:owner-fluka-discuss_at_mi.infn.it]
On Behalf Of Fasso, Alberto
Sent: 11/09/2020 12:37
To: Riya Dey <riyadey_at_barc.gov.in>; fluka-discuss_at_fluka.org
Subject: [SPAM] Re: [fluka-discuss]: comparison of photon fluence from
mgdrawBDX and USRBDX USRBDX

Dear Riya Dey,
I am sorry that I misunderstood the purpose of your calculation. Indeed, if
you are scoring at a boundary in a two-step calculation, using mgdraw is the
right choice. But if you want to check with USRBDX, you must choose one-way
current scoring (WHAT(1)=1.0)

Alberto

________________________________________
From: Riya Dey <riyadey_at_barc.gov.in>
Sent: Wednesday, September 9, 2020 10:02 AM
To: Fasso, Alberto; fluka-discuss_at_fluka.org
Subject: RE: [fluka-discuss]: comparison of photon fluence from mgdrawBDX
and USRBDX

Dear Alberto,

Thank you for your quick response. I have attached here the mgdrawBDX that I
used where I have collected the position coordinate, direction cosines,
energy and weight. I have to use mgdrawBDX since I am using a two-step
simulation.

 In the 1st simulation, I scored photon distribution using mgdrawBDX (the
position coordinate, direction cosines, energy and weight) and in the 2nd
simulation, I used these data as input (by reading a txt file containing
outputs from mgdrawBDX) to estimate dose.

In the 1st simulation, I have added USRBDX card, to verify the correlation
between the outputs from USRBDX and mgdrawBDX where I found the previous
discrepancy.

It will be very helpful, if you can guide me on this.

-----Original Message-----
From: Fasso, Alberto [mailto:fasso_at_slac.stanford.edu]
Sent: 09 September 2020 13:15
To: Riya Dey <riyadey_at_barc.gov.in>; fluka-discuss_at_fluka.org
Subject: Re: [fluka-discuss]: comparison of photon fluence from mgdrawBDX
and USRBDX

Dear Riya Dey,
the ratio between the USRBDX results and that obtained by you with mgdraw is
nearly exactly 2. Therefore, it is obvious that with mgdraw you have not
scored fluence, but current.
See any of the FLUKA course lectures:
"In an isotropic field can be easily seen that on a flat surface J = Ö/2"
Indeed, did you take into account the cosine of the crossing angle? It is
not an easy task, especially for grazing particles crossing the boundary.
One important lesson you should learn is to trust the built-in FLUKA scoring
algorithms, which are nearly always much better than what you can try to do
by yourself with mgdraw or other user functions

Alberto

________________________________________
From: owner-fluka-discuss_at_mi.infn.it <owner-fluka-discuss_at_mi.infn.it> on
behalf of Riya Dey <riyadey_at_barc.gov.in>
Sent: Wednesday, September 9, 2020 5:54 AM
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: comparison of photon fluence from mgdrawBDX and
USRBDX

Dear FLUKA experts,

In a simulation, mgdrawBDX has been used to obtain photon distribution from
void to target. The total no of data point obtained is 243341 for 5E+9
primaries (no of history = 1E+8, spawn = 10, cycle = 5). Then from this
information, photon fluence is 4.86682E-5 particle/primary.

At the same time I have used USRBDX card with one way scoring from void to
target and fluence is ( --> (Part/pr) 9.6862677E-05 +/-
0.3224583 % ).

From my understanding, these two numbers should match.

Can you please guide me in this matter ?

Thanks and Regards

~~~~~~~~~~~~~~~~~~~~~~~~~
Riya Dey




__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info



** Radiation exposure to public from NPP is negligible **

Disclaimer
----------

This email and any files transmitted with it are intended solely for the use of the addressed individual or entity. It contains information that is confidential and protected from disclosure. It must not be printed, read, copied, disclosed, forwarded, distributed or used (in whatsoever manner) by any person other than the addressee. Unauthorized use, disclosure or copying is strictly prohibited and may constitute unlawful act and can possibly attract legal action.

Please note that any views or opinions presented in this email are solely those of the author and do not necessarily represent those of the company. The recipient should check this email and any attachments for the presence of viruses. The company accepts no liability for any damage caused by any virus transmitted by this email.

If you have received this message in error, you should destroy this message and may please notify the sender by e-mail.
Thank you.
-----------


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Sep 11 2020 - 10:55:23 CEST

This archive was generated by hypermail 2.3.0 : Fri Sep 11 2020 - 12:24:35 CEST