[fluka-discuss]: Dose estimation using Energy score with USRBIN and dose-eq score with AUXSCORE

From: <ashishsingh_at_barctara.gov.in>
Date: Mon, 21 Dec 2020 11:19:41 +0530

Dear Fluka Experts,


I am trying to score dose inside a 5 cm sphere (detector) for 1 MeV photons.
The source is a cylindrical source of 5 cm radius and 10 cm height.


Dose obtained in USERBIN is 0.85 x 10E-06 pGy/primary (by converting energy
to dose).


While air ambient dose equivalent obtained using AUXSCORE combined with
USERBIN is obtained as 41.3 x 10E-06 pSv/primary



I am unable to figure out this discrepancy obtained using these two cards.
Please suggest me why this discrepancy obtained. The input and output files
are attached here.





Thanks in advance

Ashish




__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info

Received on Mon Dec 21 2020 - 09:20:53 CET