Re: [fluka-discuss]: RESNUCLEI error

From: <alfredo.ferrari_at_mi.infn.it>
Date: Thu, 31 Mar 2022 22:05:06 +0200

Dear Sebastiano

are you sure that you recompiled/relinked usrsuw.f (and the other utilities)
in the flutil directory when installing the latest respin? Also, are the
various binary files, in particular nuclear.bin inside the fluka
installation directory up-to-date?

It seems there is an inconsistency between your usrsuw utility and
the nuclear.bin file.

Alfredo

> Dear Fluka expert,
> I've encountered the following problem when I try to process the data
> files
> after the run. (see images attached)
> In particular, this kind of error appears when the input file contains a
> RESNUCLEI card. Instead, when RESNUCLEI card is not present in the input,
> Fluka processes the data correctly.
> How can I fix this problem?
> Thanks
>
> --
>
>