Dear FLUKA experts,
We have recently installed the last FLUKA version 2021.2.6 and I wanted to try to score DPA-NRT, a functionality added a couple of versions ago if I'm not mistaken. Unfortunately I cannot find the "Part:" in the USRBIN scoring card. In the FLUKA manual I found that DPA-NRT is particle 259, so I put that value manually into the card but then FLUKA gives an error "Particle 259 not found!".
To confirm that the right version is being used I run a short simulation and checked the output, "FLUKA2021 Version 2.6 May-22 by A.Ferrari DATE: 6/23/22 TIME:12.59:45"
Any possible causes for that error?
Thanks,
Ferran Boix Pamies
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info