--_968a0db4-627e-4304-9f7a-b4c05d616564_
Content-Type: text/plain; charset="ks_c_5601-1987"
Content-Transfer-Encoding: 8bit
Dear FLUKA experts,
I want to obtain neutron dose equivalent score ( unit ¥ìSv/h).
To see it, I used USRBIN estimator including AUXSCORE.
I'm not sure if 8.4959E+01 value (in fort.** file from FileViewer)
is dose equivalent- ¥ìSv/h?
Kind Regards.
Turgay KORKUT
Agri Ibrahim Cecen University
Science and Art Faculty
Physics Department
TURKEY
turgaykorkut_at_agri.edu.tr
USRBIN CARD
USRBIN 10. DOSE-EQ 35. 0.855 0.855 5.12DE05
USRBIN -0.855 -0.855 5.07 1. 1. 1.&
AUXSCORE USRBIN ALL-PART DE05 AMB74
fort.** file from FileViewer
***** BB4 956 MeV/n 56-Fe, H2O *****
DATE: 12/11/ 9, TIME: 9:54: 9
Total number of particles followed 11645, for a total weight of 1.1645E+04
1
Cartesian binning n. 9 "DE05 " , generalized particle n. 240
X coordinate: from -8.5500E-01 to 8.5500E-01 cm, 1 bins ( 1.7100E+00 cm wide)
Y coordinate: from -8.5500E-01 to 8.5500E-01 cm, 1 bins ( 1.7100E+00 cm wide)
Z coordinate: from 5.0700E+00 to 5.1200E+00 cm, 1 bins ( 5.0000E-02 cm wide)
Data follow in a matrix A(ix,iy,iz), format (1(5x,1p,10(1x,e11.4)))
accurate deposition along the tracks requested
this is a track-length binning
8.4959E+01
Received on Fri Dec 11 2009 - 11:00:28 CET
This archive was generated by hypermail 2.2.0 : Fri Dec 11 2009 - 11:00:28 CET