RE: 50keV protons: Dose calculation in nanometer thickness

From: Mario Santana Leitner <Mario.Santana_at_cern.ch>
Date: Wed, 26 May 2010 05:45:13 +0200

With a thin target I would try to bias the (inelastic hadronic)
interaction length, please check:

http://www.fluka.org/fluka.php?id=man_onl&sub=45

Also since your beam energy is low, check that you have low enough
cut-offs for your EM cascades:

http://www.fluka.org/fluka.php?id=man_onl&sub=29

-----Original Message-----
From: owner-fluka-discuss_at_mi.infn.it on behalf of =
turgaykorkut_at_hotmail.com
Sent: Tue 5/25/2010 9:04 AM
To: fluka-discuss_at_fluka.org
Subject: 50keV protons: Dose calculation in nanometer thickness

Dear FLUKA users,

I want to calculate DOSE using USRBIN. My target is four oxide mixture
which has 5 nanometer thickness.
Dose results of simulation 0.000. Which cards should I use?

Best wishes.

Turgay Korkut

turgaykorkut_at_hotmail.com
Received on Wed May 26 2010 - 09:44:51 CEST

This archive was generated by hypermail 2.2.0 : Wed May 26 2010 - 09:44:57 CEST