Re: scoring of neutron

From: George Kharashvili <georgek_at_jlab.org>
Date: Wed, 01 Dec 2010 10:50:33 -0500

Dear Mojdeh,

The input file is missing PHOTONUC card.
The region named "ioncham" (not "ionchamb") is not assigned any
material, which makes it a black hole by default.
Also, are you sure you want your beam divergence to be isotropic?
Please, double check your BEAM and BEAMPOS cards.

Cheers

   - George

On 12/1/2010 7:21 AM, mojdeh najm wrote:
>
> Dear FLUKA users
>
> I simulated head of CLINAC with 18MV of energy, So that I prepared
> attached file and I’ll expect to score low energy neutron (up to 10
> MeV) but I can’t get any results in neutron and other scores. Please
> take a look to my file and give me advice.
>
> Regards
>
> Mojdeh Najm
>

-- 
    George Kharashvili                  |  Tel:     +1 (757) 269-6435
    Jefferson Lab Radiation Control     |  Fax:     +1 (757) 269-6050
    12050 Jefferson Avenue, MS 6B       |  E-mail:   georgek_at_jlab.org
    Newport News, Virginia 23606, USA   |
Received on Wed Dec 01 2010 - 17:44:31 CET

This archive was generated by hypermail 2.2.0 : Wed Dec 01 2010 - 17:44:32 CET