Re: problem with USRYIELD

From: Hamideh Jalali <jalali.hb_at_gmail.com>
Date: Tue, 11 Jan 2011 12:26:10 +0330

(smtp1.mi.infn.it [192.84.138.69]); Tue, 11 Jan 2011 09:56:17 +0100 (CET)
Sender: owner-fluka-discuss_at_mi.infn.it

Dear Sunil

Thanks a lot for your response. But this part of is a little vague for me:

>
> The steradian can be converted to unit area at a distance (solid angle sr to cm-2, you can use the ICRP or Maurizio Pelliccioni's fluence to
dose conversioncoefficients given in units of pSvcm2 and obtain dose
equvalent.
>
As I mentioned I normalize results to surface area so I get dose
equivalent in pSv/GeV.sr/primary which means I've use fluence to dose
conversion coefficients in units of pSvcm2 once. Now if I convert sr
to cm-2 which coefficients can omit cm-2. And what is the correct
value of r? Is it optional!?

Kind Regards
Hamideh

> On Mon, Jan 3, 2011 at 1:16 PM, Hamideh Jalali <jalali.hb_at_gmail.com> wrote:
>>
>> Dear FLUKA users
>>
>> In my problem a 3GeV electron beam strike a target of iron and I'm
>> going to score gamma and neutron dose equivalent in angles 0 and 90
>> degree with respect to beam direction around the wall of concrete. So
>> I used USRYIELD for this aim but in 0 degree, the results are one or
>> two order less than what I expected and  in 90 degree, the results are
>> zero. Please guide me where I am wrong?
>> The other question, as I've got I can set angles in USRYIELD in radian
>> or degree but the results are in sr and if I normalize results to
>> surface area I will obtain dose equivalent in pSv/GeV.sr/primary. Now
>> I want to find dose equivalent in pSv/primary, is it correct if I
>> multiply cumulative spectrum by angular interval width in radian?
>> the input file is attached.
>>
>> Best Regards
>> Hamideh
>
>
Received on Wed Jan 12 2011 - 00:37:53 CET