Re: Is it possible to discriminate the dose and the deposited energy produced by different kind of particles?

From: Vittorio Boccone <boccone_at_cern.ch>
Date: Wed, 16 Mar 2011 23:52:56 +0100

Dear Denny,
  yes use the AUXSCORE card
     Some Examples (from the manual):
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....
  USRBIN 10.0 208.0 -50.0 10.0 10.0 10.0Ene.p
  USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
  AUXSCORE 2.0 1.0 1.0
  * The above AUXSCORE card will filter the energy scoring of the
  * USRBIN card to only the energy that is deposited by protons

  USRBIN 10.0 ENERGY -50.0 10.0 10.0 10.0Ene.pi
  USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
  AUXSCORE USRBIN MUONS Ene.pi
  * Similar to the previous example but in a name based input

  USRBIN 10.0 DOSE-EQ -50.0 10.0 10.0 10.0DoseEq
  USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
  AUXSCORE USRBIN DoseEq AMB74
  * Score ambient dose equivalent in a Cartesian mesh from all particles

  USRYIELD 124.0 ALL-PART -87. TARGS3 INAIR 1.0 Fe56
  USRYIELD 180.0 0.0 18. 10.0 0.0 3.0 &
  AUXSCORE 5.0 -5602600. Fe56 Fe56
  * Score yield of 56 Fe ions

cheers
V.

On 03/16/2011 06:27 AM, dengmw_at_student.sysu.edu.cn wrote:
> Dear all,
>
> As you know,dose and deposited energy are produced by at least one kind of
> particle.So is it possible to discriminate the dose and the deposited
> energy produced by different kind of particles?That is to say,can I know
> that how much dose and deposited energy is produced by one particular kind
> of particle,and how much is produced by another kind of particle,if there
> are 2 particles involved.
>
> Yours sincerely,
> Danny
>
>

-- 
  CERN EN/STI-EET
  Address :   CERN, CH-1211 Geneve 23, Switzerland
  E-mail  :   vittorio.boccone_at_cern.ch
  Office  :   75821 (from ext.  +41 22 767 5821)
  GSM     : 16-5737 (from ext.  +41 76 487 5737)
Received on Thu Mar 17 2011 - 17:34:21 CET