You can write an offline program which filters the relevant lines,
identified by A and Z, from the average output files from RESNUC
generated by usrsuw.f . Since the gases are collected in a container,
you can get an estimate of the (ambient) dose rate by multiplying the
activities thus obtained with the gamma-constant, i.e. the dose rate per
unit activity, and with 1/distance^2.
------------------------------------------------
Thomas Otto
Safety Officer Technology Department
TE-HDO
CERN
CH-1211 Geneve 23
Tel (+41)(0) 22 76 73272
GSM (+41)(0) 76 487 0648