[fluka-discuss]: How to kill secondary electrons?

From: <yyc2011_at_mail.ustc.edu.cn>
Date: Wed, 22 Jan 2014 10:07:08 +0800 (CST)

Dear Fluka users,
  
  If I want to kill secondary electrons,what should I do? Could you tell me in detail or could you give me a simple example?
  Thanks for any suggestion.

Best Regards
Chen Yuan


   


> -----Original E-mail-----
> From: "Vasilis Vlachoudis" <Vasilis.Vlachoudis_at_cern.ch>
> Sent Time: 2014-1-10 22:48:21
> To: "yyc2011_at_mail.ustc.edu.cn" <yyc2011_at_mail.ustc.edu.cn>, "fluka-discuss_at_fluka.org" <fluka-discuss_at_fluka.org>
> Cc:
> Subject: RE: [fluka-discuss]: Exchange the lower bound of the region with the upper bound of the region in EMFCUT
>
> Hi Chen,
>
> No you cannot exchange the upper/lower bound the order should be the same as they appear in the input file.
> Always verify in the output <inputname>001.out that the thresholds understood by the code are the ones you wanted.
> Concerning your other emails. Use USRBIN with binary output and to be able to process the file and plot the results.
> You can only play with the thresholds EMFCUT to kill secondary electrons
>
> Look the flair tutorial http://www.fluka.org/flair/flair_basic1.pdf
> and the course slides especially the one on scoring
> https://www.fluka.org/free_download/course/dresden2013/Lectures/07_Scoring_1013.pdf
>
> Vasilis
>
>
> ________________________________________
> From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of yyc2011_at_mail.ustc.edu.cn [yyc2011_at_mail.ustc.edu.cn]
> Sent: 08 January 2014 03:40
> To: fluka-discuss_at_fluka.org
> Subject: [fluka-discuss]: Exchange the lower bound of the region with the upper bound of the region in EMFCUT
>
> Dear everyone,
>
> When I use EMFCUT command to set electron transport energy cutoff,Can I exchange the lower bound of the region with the upper bound of the region in EMFCUT?The attachment is my input file.The EMFCUT is set as follows.
> EMFCUT -0.00001 0.000001 VOID left
> When I exchange the lower bound of the region with the upper bound of the region,the EMFCUT is set as follows.
> EMFCUT -0.00001 0.000001 left VOID
> I find the result becomes quite different.For this result,I can't understand.
> So,
> (1)Could I exchange the lower bound of the region with the upper bound of the region in EMFCUT?And Why?
> (2)Could you give me a simple schematic plot to explain which is the the lower bound of the region and which is the upper bound of the region?
>
> Best Regards
> Chen Yuan
>
>
>