Re: [fluka-discuss]: Filter on resnuclei scoring

From: Vittorio Boccone <dr.vittorio.boccone_at_ieee.org>
Date: Sat, 15 Feb 2014 22:13:22 +0100

Dear Chris,
    I would use the WHAT(2) of AUXSCORE
               <= -100.0 Isotope coding. To select atomic number Z, mass
                          number A and isomeric state M
                          what(2)= -(Z*100+A*100000+m*100000000).
                          Z=0 means all atomic numbers for the given A,
                          A=0 includes all mass numbers for a given Z,
                          M=0 includes all ground and isomeric states.
                         To select only the ground state set M=9

but maybe I miss the point of your question?
Best,
V.

On 2/14/2014 10:13 AM, Chris Theis wrote:

> Dear all,
>
> Does anyone know by chance if and how it is possible to filter the
> scoring of a specific isotope via the RESNUCLE card? It seems that
> AUXSCORE is not applicable and I tried to implement a usrrnc.f routine
> which sets the weight (WEE) to zero for isotopes that I'm not
> interested in. However, it didn't seem to have an effect even though I
> could confirm that the routine was called.
>
> Thanks a lot
>
> Chris
>
Received on Sun Feb 16 2014 - 00:22:12 CET