[fluka-discuss]: RE: minimum irradiation time in IRRPROFI card?

From: <tristan.davenne_at_stfc.ac.uk>
Date: Wed, 2 Jul 2014 13:29:27 +0000

I wondered if someone had replied to this question and I missed it in my email, havn't seen anything but the email system was playing up last week.

Thanks

From: Davenne, Tristan (STFC,RAL,TECH)
Sent: 23 June 2014 12:42
To: fluka-discuss_at_fluka.org
Subject: minimum irradiation time in IRRPROFI card?

Dear FLUKA experts,

I would like to work out the residual activity in a target following a single proton beam pulse that lasts of order of microseconds.

Can you tell me what the minimum accepted irradiation time in the IRRPROFI card is? I seem to have trouble getting a solution with irradiation times less than 1 second. Is it reasonable to assume my pulse lasted one second as long as I apply the right total number of protons in the pulse or would this be inaccurate?

Many Thanks

Tristan


-- Scanned by iCritical.
Received on Wed Jul 02 2014 - 16:58:47 CEST