[fluka-discuss]: how to record the radioactivity products after an enough cooling time

From: ³Â½¨ç÷ <chenjianqi_at_impcas.ac.cn>
Date: Thu, 31 Jul 2014 16:34:53 +0800 (GMT+08:00)

Dear Fluka experts
     I came to a annoying problem when I used fluka recently. I wanted to record the radioactivity products after an enough cooling time, for example 2 years. According to the content in discussion between you with Islam ,http://www.fluka.org/web_archive/earchive/new-fluka-discuss/5094.html , I also used USRBDX detector with the help of fluscw.f to try to solve this problem, but I gained the unexpected result. Afterwards, I found the problem existed in DCYSCORE with the fluscw.f , for a factor used for scoring time is not available in user routines such as fluscw.f. I wonder if you have some good ideas to help me solve this question, How to record the radioactivity products after an enough cooling time?
  
      Thanks in advance
                                                                                                                                                                                  With best regards,
                                                                                                                                                                                             Jianqi Chen









Received on Thu Jul 31 2014 - 12:24:52 CEST