Dear Roxana Rata
I suggest to always inspect the output file. There you will find a message
that ACTIVITY cannot be scored with USRBIN using What(1)=11. The latter
requires scoring along the step, apportioned among different bins, which
makes sense, e.g., for fluence, but not for activity which is produced at
a certain spot. Please change What(1)=1 and it should work.
Cheers
Stefan
___________________________________
Stefan Roesler
CERN, DGS-RP
CH-1211 Geneva 23
Switzerland
Phone: +41-22-7679891
Fax: +41-22-7669639
E-mail: Stefan.Roesler_at_cern.ch
On Wed, 14 Jan 2015, Roxana-georgiana Rata U1179323 wrote:
> Dear FLUKA experts,
>
> I am trying to simulate the activation of the collimator for a 60 MeV proton beam. I am
> using a simple geometry: the nozzle, the collimator and the water phantom. I defined
> only 2 decay times : 1 hour and 1 month.
> I am interested to calculate the activity and the dose equivalent rate.
> The problem is that when I am trying to run the simulation, at the progress status is
> saying waiting to attach files and after that FINISHED OK. There are no errors shown
> but also no files created.
> Could you pls check my input and tell me what am I doing wrong?
>
> Thank you.
>
> Regards,
>
> Roxana Rata
>
>
>
> University of Huddersfield inspiring tomorrow's professionals.
> [EmailSigFooter.jpg]
>
> This transmission is confidential and may be legally privileged. If you receive it in
> error, please notify us immediately by e-mail and remove it from your system. If the
> content of this e-mail does not relate to the business of the University of
> Huddersfield, then we do not endorse it and will accept no liability.
>
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Jan 15 2015 - 00:11:56 CET