Dear Fluka users£¬

 

 

I have a small question using usyield. I tried to use usryield to score photon dose at different polar angles under the condition of 10MeV electron hitting high-Z target. But except at 0 degree ,the results at other angles shows 0.

  my input file and results are attached. So I wonder if usryield can be used to score the angular dose distribution or something else in my input files is not corrected. Actually I want to study the angular dose distribution around the target.

 If usryield can not do it , are there any other practical methods? Thank you very much.

 

Bo yang

 

TITLE
Hard X-ray generated by electron-Gold collisions
* yangbo 2013/10/22
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
DEFAULTS PRECISIO
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----*
BEAM -0.01 0.0 0.0 0.0 0.0 0.0ELECTRON
BEAMPOS 0.0 0.0 -0.0001 0.0 0.0
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----*
GEOBEGIN 0.0 COMBNAME
    0 0 only scoring spheres
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
RPP Blabox -5000000.0 +5000000.0 -5000000.0 +5000000.0 -5000000.0 +5000000.0
RPP Vacbox -1000000.0 +1000000.0 -1000000.0 +1000000.0 -1000000.0 +1000000.0
RCC TARGET 0. 0. 0. 0. 0. 0.28 0.28
SPH BALL 0. 0. 0. 100.
END
* -reg-----or-----or-----or-----or-----or-----or-----or-----or-----or-----
BL1 5 +Blabox -Vacbox
VA2 5 +Vacbox -BALL
TC3 5 +TARGET
SP4 5 +BALL -TARGET
END
GEOEND
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----*
ASSIGNMA BLCKHOLE BL1
ASSIGNMA VACUUM VA2
ASSIGNMA TANTALUM TC3
ASSIGNMA VACUUM SP4
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----*
EMF-BIAS 1022. 0.0 0.0 TC3 TC3 0.0
EMFCUT -1.0E-5 1.0E-6 0.0 VACUUM TANTALUM PROD-CUT
EMFCUT -1.0E-5 1.0E-6 0.0 TC3 SP4
* Scoring *
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----*
USRYIELD 114. DOSE-EQ -64. SP4 VA2 1.Pho6
USRYIELD 0.8 0.0 5. 0.01 0.0 6.&
AUXSCORE USRYIELD PHOTON Pho6 Pho6 EWT74
* --+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----*
RANDOMIZ 1. 139.
START 100000000.
STOP

 

# Detector n: 1 Pho6

 # N. of x1 intervals 5

   0.000000 0.1600000 11412.72 6.9665097E-02

  0.1600000 0.3200000 0.000000 0.000000

  0.3200000 0.4800000 0.000000 0.000000

  0.4800000 0.6400000 0.000000 0.000000

  0.6400000 0.8000000 0.000000 0.000000



__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Mon May 11 2015 - 16:54:14 CEST

This archive was generated by hypermail 2.3.0 : Mon May 11 2015 - 16:54:15 CEST