- For your USRBIN card called “Netro”, you are scoring prompt dose rate (you are not associating a cooling time). In that case the results will be pSv/primary particle.
To obtain Sv/h you need to normalize the results to your beam intensity in protons per second for example (seems to be 1.08e06 protons / sec from your irradiation profile definition, which seems quite low ?) and then multiply by 3600 (sec -> hour) and divide by 1e12 (pSv -> Sv).
- For the USRBINs Netro4/5/7/8 the results are pSv/s for the dose rate at the specified cooling time (you are using DCYSCORE). To have Sv/h multiply by 3600 and divide by 1e12.