Re: [fluka-discuss]: Dose-rate

From: Lucia Sarchiapone <lucia.sarchiapone_at_lnl.infn.it>
Date: Fri, 10 Jul 2015 14:07:57 +0200

Hi,

the output of the DOSE-EQ usrbin associated to the AUXSCORE, as you defined it, is pSv/primary particle (proton in your input). So if you need your results in Sv/hour you have to multiply by the number of protons/hour and the right power of 10 to obtain milliSv, microSv or Sv from the picoSv. This will be prompt dose rate.
When you define an irradiation profile and you associate a DCYSCORE card to your USRBIN DOSE-EQ scoring, results will be in pSv/second. In order to get Sv/h the multiplication factor is 3,6e-9. This is the residual dose rate.
Hope this helps,

Regards,

Lucia


> Il giorno 10/lug/2015, alle ore 12:17, NKANYISO ROBERT Mantengu <3477531_at_myuwc.ac.za> ha scritto:
>
> Dear FLUKA users I am lost on how to normalize the results of DOSE-EQ obtained from USRBIN card with AUXSCORE card that convert DOSE-EQ to ambient dose equivalent. As far as I'm concern the results are in Sv but i need them in Sv/hour.
>
> Here I have attached my input file.
>
> Any comment will be appreciated.
>
> Regards
> N.R Mantengu.
> <OldPlan1.flair><OldPlan1.inp>

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id¬c_info
Received on Fri Jul 10 2015 - 15:52:18 CEST