Re: [fluka-discuss]: photon and neutron doses

From: Luigi Salvatore Esposito <luigi.salvatore.esposito_at_cern.ch>
Date: Tue, 27 Oct 2015 11:53:43 +0000

Hi Hans,
actually the problem is related to the ambient dose scorings when filtered out on the photons (NOT neutrons as you wrote).
For these scorings you have only 1 bin and gnuplot shows an empty distribution in this case.
If you set more bins (as for your particle fluence scoring, where you set the number of bins to 60), you will have non empty distributions.

By the way, though you have 1 bin also for the neutron dose scorings, you had no problem
since for neutrons below 20 MeV the binning is anyhow determined by the neutron group structure.

Best regards, luigi

> On 27 Oct 2015, at 09:39, Hans Beijers <beijers_at_KVI.nl> wrote:
>
> Dear FLUKA experts,
>
> I am studying angle-dependent photon and neutron spectra and doses
> produced by a 30 MeV electron beam on a tungsten disk. The photons and
> neutrons are tallied on a 5 m radius sphere which is intersected by
> cones to get the spectra and doses in angular bins 0-10 degr, 10-30
> degr, 30-60 degr, 60-120 degr and 120-180 degr. With the photons I get
> spectra and doses, but with the neutrons I get spectra, but the doses in
> the angular bins are all zero. I must be making a mistake, but I don't
> see where. Any help is greatly appreciated.
>
> Best regards,
>
> Hans
> <nph_spec_cyl.inp>