Activates the Inverse Compton option either for a uniform/diffused black body photon bath, or for a spherical source photon sourceWHAT(1)> 0.0 : Temperature T (K) of a black body photon density. T > 0 activates the treatment of Inverse Compton in vacuum < 0.0 : A negative value resets to default (no inverse Compton) = 0.0 : ignoredDefault: T=0, and no Inverse Compton is performedWHAT(2)>= 0.0 : Radius (cm) of a possible photon spherical source, the default is zero. If zero an uniform pervasive black body radiation at T=WHAT(1)is assumed. Please note that zero is a valid value < 0.0 : resets to defaultDefault: zero radius, that is uniform pervasive black body radiation at T=WHAT(1)(K)WHAT(3)= X-coordinate (cm) of the spherical source centre, if defined, meaningless forWHAT(2)=0.Default= 0.0WHAT(4)= Y-coordinate (cm) of the spherical source centre, if defined, meaningless forWHAT(2)=0.Default= 0.0WHAT(5)= Z-coordinate (cm) of the spherical source centre, if defined, meaningless forWHAT(2)=0.Default= 0.0WHAT(6)= Region index or name of the (vacuum) region where Inverse Compton must be performed. A zero value means IC performed in all vacuum regions, please note that zero is a valid value, a negative value resets to defaultDefault= 0.0SDUM: not usedNotes: