associates selected scoring detectors of given estimator type with
user-defined decay times. See WARNING in Note 1 below
See also DCYTIMES, IRRPROFI, RADDECAY, RESNUCLEi
WHAT(1) = cooling time index to be associated with the detector(s) of
estimator type defined by SDUM and with number corresponding to
WHAT(4)-WHAT(6) (see Note 2 below)
Default = 0.0 (no scoring!)
WHAT(2)-WHAT(3) = not used
WHAT(4) = lower index bound of detectors associated with the specified
cooling time
("From detector of estimator type SDUM no. WHAT(4)...")
Default = 1.0
WHAT(5) = upper index bound of detectors associated with the specified
cooling time
("...to detector of estimator type SDUM no. WHAT(5)...")
Default = WHAT(4)WHAT(6) = step length in assigning indices
("...in step of WHAT(6)")
Default = 1.0
SDUM : identifies the kind of estimator under consideration: EVENTBIN,
RESNUCLEi, USRBDX, USRBIN, USRCOLL, USRTRACK, USRYIELD
Default: no default!
Default (option DCYSCORE not requested): no detector is associated with any
cooling time index
Notes:
1) WARNING: when the DCYSCORE option is applied to a detector, all
quantities are expressed PER UNIT TIME. For instance, the RESNUCLEi
estimator will output Bq, dose estimators will provide dose rate,
etc.
2) The cooling time index indicated by WHAT(1) must be one of those
defined by means of option DCYTIMES.
3) USRBIN and EVENTBIN estimators are counted together (they belong to
the same index sequence), and so are USRTRACK and USRCOLL
Example:
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
DCYTIMES 86400. 172800.
DCYSCORE 1. 0. 0. 4. 8. 2.USRBIN
DCYSCORE 2. 0. 0. 1. 5. USRTRACK
* Two cooling times have been defined. Binnings no. 4, 6 and 8 will be
* associated to the first cooling time (one day), and track-length detectors
* no. 1, 2, 3, 4 and 5 will be associated to the second cooling time (2 days)