Re: low energy n xsec

From: Alfredo Ferrari (alfredo.ferrari@cern.ch)
Date: Wed Aug 04 2004 - 09:53:26 CEST

  • Next message: LEE, KERRY T. (JSC-SR) (UHCL): "USER SOURCE"

    The id's for NITROGEN changed. Do you have a LOW-MAT card for NITROGEN?

    If so the second id should become -2 as per the list in the new manual.

                        Alfredo

    On Tue, 3 Aug 2004, Georgios Tsiledakis wrote:

    >
    > Dear all,
    > I have just downloaded the latest version of FLUKA (flukalinuxAA.tar).
    > When I run the same input file I was using with success during the
    > previous FLUKA release,...,despite the fact that I have modified all
    > the scoring routines according to the newest versions, I had an error...
    > The .out file finishes as following:
    >
    > ***** Neutron Xsec: ****
    > **** Group limits, average energies, velocities ....
    >
    > *** Recoil proton production activated for Morse mat. # 1 ***
    > **** Low energy neutron xsec not found for some media 32 33 ****
    > .....................................
    > Does this imply anything??
    > The 32, 33 are the number indexes in the MATERIAL card for 132-Xenon and
    > 134-Xenon isotopes respectively...
    > I have no idea what else has changed...
    > Thank you very much in advance.
    > Kind regards
    > Georgios
    >

    -- 
    +----------------------------------------------------------------------------+
    |  Alfredo Ferrari                ||  Tel.: +41.22.767.6119                  |
    |  CERN-AB                        ||  Fax.: +41.22.767.7555                  |
    |  1211 Geneva 23                 ||  e-mail: Alfredo.Ferrari@cern.ch        |
    |  Switzerland                    ||          Alfredo.Ferrari@mi.infn.it     |
    +----------------------------------------------------------------------------+
    

  • Next message: LEE, KERRY T. (JSC-SR) (UHCL): "USER SOURCE"

    This archive was generated by hypermail 2.1.6 : Wed Aug 04 2004 - 10:13:58 CEST