Is there a maximum number of energy bins in USRTRACK card ?

From: Sebastien WURTH (wurth@ipno.in2p3.fr)
Date: Mon Mar 19 2007 - 16:40:25 CET

  • Next message: Giuseppe Battistoni: "Re: optical photons for electron from muon decay and muon"

    Hello everybody,

    I wanted to use an "old" (from fluka2005.6 version) input file of mine.
    I described a USRTRACK card with WHAT(6)=1000 energy bins.
    I got results then, no problem by using ustsuw.
    But, with the last version, fluka2006.3.3 and associated ustsuw, I got
    an error message :
    "subscript out of range on file line 673, procedure ustsuw.f/MAIN
    Attempt to access the 1000-th element of variable epgmax"

    And the output files from fluka2006.3.3 still go OK through ustsuw
    program from 2005.6 version, I got my spectrum with my 1000 energy bins.
    So I didn't compare the 2 files line by line, but at line 673 it's the
    same : EPGMAX(IG) = ENERGE

    My question is : Is there a restriction now in the number of energy bins
    ? I only find the restriction of the number of detector (400) in the
    manual...
    Any clue would be helpful.

    PS : I use a source.f routine in the run sampling an Eu152 photon
    source, but I don't think it is relevant here, since I got the same
    message by using standard flukahp and SOURCE card switched off.

    Thanks.
    Sebastien.