Re: [fluka-discuss]: Comscw - RULL of exactly 1GeV

From: <me_at_marychin.org>
Date: Thu, 06 Apr 2017 20:23:09 +0800

Dear Sebastian,

RULL=1 indeed looks like a number too nice and round to be true. The
first thing to check is if the unit is really GeV. You might like to
write out ISCRNG and see. My wild guess is that ISCRNG could be 2, which
means 1 star, not 1 GeV.

When scoring RULL with comscw, typically we filter with ISCRNG and
JSCRNG to avoid counting more than we actually intend.

:) mary

On 2017-04-06 19:12, Meyer.Se_at_physik.uni-muenchen.de wrote:
> Dear FLUKA community,
>
> I am simulating a helium-ion beam and I score the energy deposition in
> several air regions (using the comscw routine). I realized cases for
> which the energy deposition (RULL) of a 4-helium is exactly 1GeV,
> which is already strange since the beam energy is just around
> 170MeV/u. In addition, I found that ICALL is 420 and not 131 as all
> other energy deposition events.
>
> Can someone explain me what happened?
>
> Kind regards,
> Sebastian
>
>
> --
> Sebastian Meyer
> PhD student
>
> Ludwig-Maximilians-Universität München
> Chair for Experimental Physics - Medical Physics
> Am Coulombwall 1
> D-85748 Garching
>
> room: 125
> phone: (+49) 89 289-54022
> e-mail: Meyer.Se_at_physik.uni-muenchen.de
>
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Apr 06 2017 - 15:31:17 CEST