Re: [fluka-discuss]: ENDIST(12) = missing energy

From: Andrea Fontana <andrea.fontana_at_pv.infn.it>
Date: Thu, 13 Apr 2017 17:55:16 +0200

Dear Alexander,
    the meaning of "missing energy" in Fluka is well explained
in this old message:

http://www.fluka.org/web_archive/earchive/new-fluka-discuss/0734.html

Its value depends on the physical processes involved in your
simulation and cannot be controlled independently from the physics.

Hope this helps,
Andrea

Il 12/04/2017 22:22, panov_at_dec1.sinp.msu.ru ha scritto:
> Dear FLUKA users/developers,
>
> Could you explain, what does mean exactly the parameter
>
> ENDIST(12) = missing energy
>
> in the header of events? (see EVENTDAT description in the FLUKA manual).
> I observed that the magnitude of ENDIST(12) correlates with the events
> that may look not quite correct.
> Therefore, there is an other side of the question: can I control the
> value of ENDIST(12) to make it lower?
> Or, generally, what I should do to make ENDIST(12) small?
>
> Best regards,
> Thank you in advance,
> Alexander Panov
>
> __________________________________________________________________________
>
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info
>

-- 
========================================================================
Dr. Andrea Fontana                    tel: +39 0382 987991
Istituto Nazionale                    fax: +39 0382 423241
di Fisica Nucleare
Sezione di Pavia                      e-mail: andrea.fontana_at_pv.infn.it
Via Bassi 6                           web   : www.pv.infn.it/~fontana
27100 PAVIA, Italy
========================================================================
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Apr 13 2017 - 19:08:18 CEST

This archive was generated by hypermail 2.3.0 : Thu Apr 13 2017 - 19:08:19 CEST