[fluka-discuss]: RE: Stopping power ratios from inline calculations

From: Vasilis Vlachoudis <Vasilis.Vlachoudis_at_cern.ch>
Date: Wed, 28 Jun 2017 06:49:27 +0000

Hi Ana,

you can dump the dE/dx tables for the materials used in your input, using the DELTARAY card, and enable the sdum: PRINT

Vasilis
________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Ferreira De Almeida Lourenco, Ana [am.lourenco_at_ucl.ac.uk]
Sent: Tuesday, June 27, 2017 16:09
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Stopping power ratios from inline calculations

Dear Fluka experts,

Stopping power ratios are important for dosimetry using ionization chambers since they are part of the conversion of ionization in air to dose to water.

Ideally the cavity integrals required for the stopping power ratio calculation are all calculated inline within the Monte Carlo simulation avoiding problems with the resolution of binning.

I would like to ask if it would be possible to compute stopping power ratios directly from inline calculations using FLUKA rather than first calculating the fluence differential in energy and then separately averaging the stopping powers over the calculated spectra?

Many thanks,
Ana



__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Wed Jun 28 2017 - 10:50:33 CEST

This archive was generated by hypermail 2.3.0 : Wed Jun 28 2017 - 10:50:37 CEST