[fluka-discuss]: RE: Stopping power ratios from inline calculations

From: Vasilis Vlachoudis <Vasilis.Vlachoudis_at_cern.ch>
Date: Thu, 29 Jun 2017 08:32:12 +0000

You can use the "USERWEIGHT" card and activate the call to fluscw.f.
Copy the fluscw.f from $FLUPRO/usermvax to your directory and
modify it there to adjust the weight (FLUSCW) of the scored quantity.

Vasilis

________________________________
From: Ferreira De Almeida Lourenco, Ana [am.lourenco_at_ucl.ac.uk]
Sent: Wednesday, June 28, 2017 15:35
To: Vasilis Vlachoudis; fluka-discuss_at_fluka.org
Subject: Re: Stopping power ratios from inline calculations


Hello Vasilis,


Thank you very much for your e-mail. We would like to make that calculation inline. Instead of scoring the averaged fluence differential in energy of charged particles in a disc of material using USRTRACK and then separately multiply it with the stopping powers (dumped by DELTARAY), we would like to make this calculation inline, i.e. during the transport to avoid problems with the resolution of the binning. Would this be possible using FLUKA?


Many thanks,

Ana

________________________________
De: Vasilis Vlachoudis <Vasilis.Vlachoudis_at_cern.ch>
Enviado: 28 de junho de 2017 06:49:27
Para: Ferreira De Almeida Lourenco, Ana; fluka-discuss_at_fluka.org
Assunto: RE: Stopping power ratios from inline calculations

Hi Ana,

you can dump the dE/dx tables for the materials used in your input, using the DELTARAY card, and enable the sdum: PRINT

Vasilis
________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Ferreira De Almeida Lourenco, Ana [am.lourenco_at_ucl.ac.uk]
Sent: Tuesday, June 27, 2017 16:09
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Stopping power ratios from inline calculations

Dear Fluka experts,

Stopping power ratios are important for dosimetry using ionization chambers since they are part of the conversion of ionization in air to dose to water.

Ideally the cavity integrals required for the stopping power ratio calculation are all calculated inline within the Monte Carlo simulation avoiding problems with the resolution of binning.

I would like to ask if it would be possible to compute stopping power ratios directly from inline calculations using FLUKA rather than first calculating the fluence differential in energy and then separately averaging the stopping powers over the calculated spectra?

Many thanks,
Ana



__________________________________________________________________________