Your input is missing a "DEFAULTS" card, so the defaults settings it assumes are the
"NEW-DEFA" of the DEFAULTS. This settings have too high energy transport threshold
for electrons and photons, so your 100keV photons will fall bellow threshold immediately
and nothing will be transported.
I would advice to add a DEFAULTS card with sdum: PRECISION
and even better lower the thresholds for electrons and photons with the EMFCUT
to as low as you need.
Cheers
Vasilis
________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Agnieszka Witkowska [witkowskaagnieszka07_at_gmail.com]
Sent: Thursday, September 07, 2017 20:12
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Incorrect USRTRACK result
Dear Fluka users,
Can You please help me to find a reason why output of my simulation gives only 0 as a result?
I am the beginner in terms of running simulations in Fluka programme. I am trying to measure electrons charge generated in given region (volume). Simulation runs successfully however the output of USRTRACK shows only 0....
I will appreciate any help and advise. I attached my .inp, .flair file and .lis file.
Best regards,
Agnieszka
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Sep 08 2017 - 21:47:49 CEST