Hi
Thank you for your response. Therefore with only new defa it consider only MCS according to Moliere theory without spin relativistic and nuclear correction. Am I correct? Now with new defa if MULSOPT option is used as "MULSOPT 1.0 -1.0 0.0 lead lead MLSH-ON" , MCS according to Moliere theory with spin relativistic and nuclear correction will be considered during transport through lead. Is it OK?
Regards
Mausumi
-----owner-fluka-discuss_at_mi.infn.it wrote: -----To: "Mausumi Sengupta Mitra" <mausumi_at_vecc.gov.in>
From: "Paola Sala"
Sent by: owner-fluka-discuss@mi.infn.it
Date: 09/12/2017 03:46PM
Cc: fluka-discuss@fluka.org
Subject: Re: [fluka-discuss]:
Hello
Spin relativistic and nuclear corrections in MCS are not activated by any
default, MULSOPT is needed
( "standard" Multiple Coulomb Scattering is activated by all defaults)
Paola
> Dear all,
I have one question regarding MCS. Whether MCS(multiple
coulomb
> scattering) according to Moliere theory with spin relativistic
> correction,
nuclear finite size effect etc., is considered with only
> Newdefa option without
using MULSOPT ?
Regards
Mausumi
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id¬c_info
Paola Sala
INFN Milano
tel. Milano +39-0250317374
tel. CERN +41-227679148
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id¬c_info
Received on Thu Sep 14 2017 - 11:48:00 CEST