Re: [fluka-discuss]: Modeling an x-ray source in FLUKA

From: Luigi Salvatore Esposito <luigi.salvatore.esposito_at_cern.ch>
Date: Sat, 14 Apr 2018 09:37:52 +0000

Dear Brian,
yes it is possible but you have to implement it in a customised source routine.
More guidance from the slides from the advanced FLUKA course about special sources from page 25.

https://indico.cern.ch/event/489973/contributions/2148893/attachments/1271819/1884943/11_AdvancedSources2016.pdf

Best, luigi



On 13 Apr 2018, at 18:38, Brian Bewer <Brian.Bewer_at_lightsource.ca<mailto:Brian.Bewer_at_lightsource.ca>> wrote:

I am trying to model the photons produced by an x-ray source in FLUKA. The flux profile would follow the function below where ‘eng’ is a value between 5keV and 250keV.
Photon Flux = exp(28.981589 + 0.030393065*eng -0.0015081001*eng^2 + 1.1646733e-005*eng^3 -4.2782251e-008*eng^4 + 5.9402665e-011*eng^5)
Is there any way to have FLUKA create primary photons with the specified energy range, and with the abundance of primary photons according to the flux profile function?
Brian


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Sat Apr 14 2018 - 13:24:53 CEST

This archive was generated by hypermail 2.3.0 : Sat Apr 14 2018 - 13:24:59 CEST