Dear Yao
unfortunately if the material is not available in FLUKA there is no clear solution.
The best approach would be to use the LOW-MAT of a material that exists in FLUKA and has a similar cross-section of interest (for your studies) with RHODIUM.
Hope this helps
regards
Lefteris
-----------------------
Eleftherios Skordis
Dep. EN/STI, CERN
CH-1211 GENEVA 23
SWITZERLAND
OFFICE: +41-22-7679541<tel:%2B41-22-7675461>
________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of yaoyang [yangyao15_at_mails.ucas.ac.cn]
Sent: 22 May 2018 14:39
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: low energy neutron xsec not found for Rhodium
Hello fluka users,
I am trying to define a detector composed of Rhodium to detect the neutrons, but the "Low energy neutron xsec not found for some media 5 6 *** RHODIUM" shows in the output file. I know that the LOW-MAT card can be used sometimes to solve this problem, but in this condition there is no corresponding low-energy neutron material find for Rhodium in the LOW-MAT. So how can I solve this problem? Any suggeations or comments will be appreciated. Thank you very much in advance.
Best regards.
Yao Yang
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Tue May 22 2018 - 19:24:35 CEST