Dear Fluka Experts,

For semi-infinite cloud model, suppose the source is a hemisphere of 450 m
radius. In this case direct scoring of energy inside a small detector volume
is not possible. What is the way out in this case?

Suppose I place a larger detector to get score of fluence and then want to
transfer that photon distribution to that earlier small detector. In this
case, it is tiresome to write manually the distribution of fluence in the
source.f file since now the fluence is a function of both energy and solid
angle. Is there any other way to do that?

 

 