On 25.06.2018 11:59, Thomas Grandsaert wrote:
> Dear fluka experts,
>
> I am trying to score optical photons in a photodiode coupled to a BGO scintillator for a wire scanner in a proton beam.
>
> There is also an aluminium foil reflector around the scintillator to increase the signal.
>
> If I run many particles, then I get a strong fluency of gammas in the scintillator, which should in theory create a shower of optical photons.
>
> I am getting zero signal on the photodiode, which is poorly named “fiber” in my input file.
>
> Could someone take a look at my input file(attached) and let me know if anything in my input file looks incorrect?
>
> And, if nothing is incorrect, some advice to get nonzero fluency on the photodiode?
>
> Finally, If I increase the number of particles to a higher number(say, 5e8), the simulation fails. (error being: aborted by kasoph-ldummy) I assume this is due to a memory error?
>
> Cheers and thanks in advance!
> T
Dear Thomas,
You didn't set refraction index for the scintillator material (mean
value is 2.15), as well as absorption and diffusion coefficients. That
gives you an optical photon generation and transport.
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....
OPT-PROP 2.15 Bi4Ge3O1
Best regards,
Mikhail
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info