RE: RE: [fluka-discuss]: Why "R-phi-Z" and "Region" didn't get same results in USRBIN?

From: Vasilis Vlachoudis <Vasilis.Vlachoudis_at_cern.ch>
Date: Tue, 30 Oct 2018 09:27:44 +0000

Hi Haoyu,

please note that the USRBIN by region is not normalized by the volume of the region
 as it is the case of the R-Phi-Z therefore you get this different result.

Vasilis
________________________________
From: Haoyu Shi [shihy_at_ihep.ac.cn]
Sent: Thursday, October 25, 2018 10:22
To: Vasilis Vlachoudis
Cc: fluka-discuss_at_fluka.org
Subject: Re: RE: [fluka-discuss]: Why "R-phi-Z" and "Region" didn't get same results in USRBIN?


Hi Vasilis,


Thanks for your help. You're right. I have a mistake. But even this, the layer1 region should be twice as the R-Phi-Z in 81 USRBIN and layer2 should be twice as 82 USRBIN, but actually, even in the wrong input file(81 USRBIN from 0 to 6.25 while layer1 region from -6.25 to 6.25), the results of 81 USRBIN is higher than layer1.


I also correct the range, and both 81 and 82 USRBIN are almost twice than layer1 and layer2 region.


I have attached the lis file, so you can see it without running and waiting(51 for layer1 region, 52 for layer2 region, 81 and 82 for R-Phi-Z). And I still get confused by these results.


Thanks a lot!


Regards,

Haoyu


-----原始邮件-----
发件人:"Vasilis Vlachoudis" <Vasilis.Vlachoudis_at_cern.ch>
发送时间:2018-10-25 15:53:43 (星期四)
收件人: "Haoyu Shi" <shihy_at_ihep.ac.cn>, "fluka-discuss_at_fluka.org" <fluka-discuss_at_fluka.org>
抄送:
主题: RE: [fluka-discuss]: Why "R-phi-Z" and "Region" didn't get same results in USRBIN?

Hi Haoyu

isn't it normal to be half your R-Phi-Z is half of the Z of the region
e.g your layer1 region extends from -6.25 to 6.2 in Z
while your 81 USRBIN is from 0 to 6.25

The same for 82

Cheers
Vasilis


________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Haoyu Shi [shihy_at_ihep.ac.cn]
Sent: Wednesday, October 24, 2018 10:45
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Why "R-phi-Z" and "Region" didn't get same results in USRBIN?


Dear FLUKA Experts,


I'm simulating the detector backgrounds. The detector is a cylinder with 0.005cm in thickness and 6.25 cm in length and made by silicon. Some electrons/positrons generate by a source file would pass the detector, and I want to get the DOSE in the detector. So I used a USRBIN card with "Region" mode and the other with "R-phi-Z" mode, both particle types was "DOSE". And the last card, I set only 1 bin in R,Phi and Z. So, to my knowledge, these two cards should get the same result. But not, the second one is almost 2 times than the first one. What's the reason for this?


The input file and the source file have been attached.


Any help or comment would be appreciated.


Regards,

Haoyu

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Oct 30 2018 - 12:00:49 CET

This archive was generated by hypermail 2.3.0 : Tue Oct 30 2018 - 12:59:51 CET