Dear experts and users,
I submited the problems several days ago, but I cannot solve it yet. Recently I have made some simulations using mgdraw.f subroutine to score the energy deposition.But there exists some unsolved problems/errors.
(attachmets: detector2.inp source.f endraw.f...)
What I want to score is the continuous energy deposition and discrete/point energy deposition, I don't know if both the two types of deposition can be accessed only with mgdraw.f. in my simulation, "source.f" samples the primary from file "detector001_ions.dat" which has 169 charged particles(71#α+ 98# Li+).
But I only obtain 11 energy-deposition events using "endraw.f" ("detector2001_endraw.dat"),as known, a charged particle will undergoes many energy-deposition or ionization events along its trajectory. so the total n number energy-deposition events should be much greater than the incident ions' number.
And another strange thing is it only obtains αdeposition events(jtrack=-6) seen in file "energy depositon in dat", not a Li+ deposition event at all, but source file has 98# Li+, why it cannot be scored, what's wrong?
any suggestion is appreciable!
Best regards!
Yang.
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
- application/octet-stream attachment: endraw.f
- application/octet-stream attachment: source.f
Received on Thu Oct 31 2019 - 14:18:08 CET