Hi,
as you can see in the manual for the USRBIN card (note 5),
energy deposition is expressed in GeV per cm3 per unit primary
weight. See also the lecture on scoring:
https://agenda.infn.it/event/20624/contributions/105895/attachments/68619/85014/AdvancedScoring2019.pdf
Kind regards,
Andrea
On 06/12/2019 13:18, 李立华 wrote:
> What is USRBIN command result's units of total deposited energy density?
>
> -----原始邮件-----
> *发件人:*"Liang, Taiee" <taiee.liang_at_desy.de>
> *发送时间:*2019-11-26 21:01:42 (星期二)
> *收件人:* "李立华" <13691416247_at_ciae.ac.cn>, fluka-discuss_at_fluka.org
> *抄送:*
> *主**题:* RE: [fluka-discuss]: to get efficient dose
>
> Dear 李立华,
>
> Please keep the emails on the fluka-discuss mailing list as well.
>
> Yes, it is possible to filter the result for effective does of neutron
> with WHAT(2) of AUXSCORE. By default it is for all particles
> “ALL-PART”, so your card should instead have either the FLUKA particle
> code “8.0” or with the name based input “NEUTRON”. In this way, your
> neutron fluence from USRBDX is multiplied by the dose conversion
> coefficients.
>
> Cheers!
>
> Ted
>
> *From:*李立华[mailto:13691416247_at_ciae.ac.cn]
> *Sent:* Tuesday, November 26, 2019 1:21 PM
> *To:* liang, taiee
> *Subject:* Re: RE: [fluka-discuss]: to get efficient dose
>
> Can neutron effective dose be obtained using this solution?
>
> best regards
>
>
> -----原始邮件-----
> *发件人:*"Liang, Taiee" <taiee.liang_at_desy.de>
> *发送时间:*2019-11-25 22:18:37 (星期一)
> *收件人:* "李立华" <13691416247_at_ciae.ac.cn>, fluka-discuss_at_fluka.org
> *抄送:*
> *主**题:* RE: [fluka-discuss]: to get efficient dose
>
> Dear 李立华,
>
> If I understand your question, I believe you are asking how to
> calculate “effective” dose from fluence using USRBDX? If so, I would
> recommend using the AUXSCORE card with your USRBDX. There are several
> sets of fluence-to-dose conversion coefficients built into FLUKA that
> you may use. Note that you also need to specify DOSE-EQ scoring for
> WHAT(2) of your USRBDX card.
>
> Below is a link to the AUXSCORE card in the manual.
>
> http://www.fluka.org/fluka.php?id=man_onl&sub=11
>
> Cheers!
>
> Ted
>
> *From:*owner-fluka-discuss_at_mi.infn.it
> [mailto:owner-fluka-discuss_at_mi.infn.it] *On Behalf Of *???
> *Sent:* Monday, November 25, 2019 11:58 AM
> *To:* fluka-discuss_at_fluka.org
> *Subject:* [fluka-discuss]: to get efficient dose
>
> Dear fluka experts:
>
> I want to get efficient dose using conversion coefficient from
> flux to efficient dose,the flux can be obtained from usrbdx card,
>
> i also obtained the exact conversion coefficient,how should i do to
> attach conversion coefficient with usrbdx card?
>
> best regards
>
>
>
> *请注意*:在您阅读本邮件时,如您了解本邮件内容涉及商业秘密,请您遵守与发信人的商务约定,保守商业机密。如您发现本邮件内容涉及重要商业秘密或与国家秘密相关,请您即刻联系发信人,确认邮件内容是否适于通过互联网传递。
>
--
========================================================================
Dr. Andrea Fontana tel: +39 0382 987991
Istituto Nazionale fax: +39 0382 423241
di Fisica Nucleare
Sezione di Pavia e-mail: andrea.fontana_at_pv.infn.it
Via Bassi 6 web : www.pv.infn.it/~fontana
27100 PAVIA, Italy
========================================================================
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Wed Dec 11 2019 - 04:38:14 CET